mirror of
https://github.com/rd-stuffs/msm-4.14.git
synced 2025-02-20 11:45:48 +08:00
hwmon: (lm90) Do not report 'busy' status bit as alarm
commit cdc5287acad9ede121924a9c9313544b80d15842 upstream. Bit 7 of the status register indicates that the chip is busy doing a conversion. It does not indicate an alarm status. Stop reporting it as alarm status bit. Signed-off-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
06613a7b30
commit
0affa7f439
@ -197,6 +197,7 @@ enum chips { lm90, adm1032, lm99, lm86, max6657, max6659, adt7461, max6680,
|
||||
#define LM90_STATUS_RHIGH (1 << 4) /* remote high temp limit tripped */
|
||||
#define LM90_STATUS_LLOW (1 << 5) /* local low temp limit tripped */
|
||||
#define LM90_STATUS_LHIGH (1 << 6) /* local high temp limit tripped */
|
||||
#define LM90_STATUS_BUSY (1 << 7) /* conversion is ongoing */
|
||||
|
||||
#define MAX6696_STATUS2_R2THRM (1 << 1) /* remote2 THERM limit tripped */
|
||||
#define MAX6696_STATUS2_R2OPEN (1 << 2) /* remote2 is an open circuit */
|
||||
@ -786,7 +787,7 @@ static int lm90_update_device(struct device *dev)
|
||||
val = lm90_read_reg(client, LM90_REG_R_STATUS);
|
||||
if (val < 0)
|
||||
return val;
|
||||
data->alarms = val; /* lower 8 bit of alarms */
|
||||
data->alarms = val & ~LM90_STATUS_BUSY;
|
||||
|
||||
if (data->kind == max6696) {
|
||||
val = lm90_select_remote_channel(client, data, 1);
|
||||
|
Loading…