mirror of
https://github.com/rd-stuffs/msm-4.14.git
synced 2025-02-20 11:45:48 +08:00
iio: pressure: bmp280: fix relative humidity unit
[ Upstream commit 13399ff25f179811ce9c1df1523eb39f9e4a4772 ] According to IIO ABI relative humidity reading should be returned in milli percent. This patch addresses that by applying proper scaling and returning integer instead of fractional format type specifier. Note that the fixes tag is before the driver was heavily refactored to introduce spi support, so the patch won't apply that far back. Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> Fixes: 14beaa8f5ab1 ("iio: pressure: bmp280: add humidity support") Acked-by: Matt Ranostay <matt.ranostay@konsulko.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Sasha Levin <alexander.levin@microsoft.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
9265a45095
commit
dc68381f49
@ -362,10 +362,9 @@ static int bmp280_read_humid(struct bmp280_data *data, int *val, int *val2)
|
||||
}
|
||||
comp_humidity = bmp280_compensate_humidity(data, adc_humidity);
|
||||
|
||||
*val = comp_humidity;
|
||||
*val2 = 1024;
|
||||
*val = comp_humidity * 1000 / 1024;
|
||||
|
||||
return IIO_VAL_FRACTIONAL;
|
||||
return IIO_VAL_INT;
|
||||
}
|
||||
|
||||
static int bmp280_read_raw(struct iio_dev *indio_dev,
|
||||
|
Loading…
x
Reference in New Issue
Block a user