mirror of
https://github.com/rd-stuffs/msm-4.14.git
synced 2025-02-20 11:45:48 +08:00
This reverts commits: - 3e846d6c4b169c44a8a08a75ff2963261dc73007 [ARM64/dts: sdmmagpie-thermal: Disable QCT default BCL throttling] - ff8e72eed55505f16bcc9cc743bd5402a2cd15aa [ARM64: dts: msm: Switch to step_wise thermal governor] - 5e8c6989b74ee02840eb1f7a5918e387df337119 [thermal: Add dummy sysfs nodes to silence mi_thermald] - 8012c0aca36923d50c8da4e00271568a802551b4 [thermal: Return before thermal trip evaluates] Change-Id: I095090a77aa38c1da92e21f612337ee767ddcd56 Signed-off-by: Richard Raya <rdxzv.dev@gmail.com>
160 lines
4.6 KiB
C
160 lines
4.6 KiB
C
/*
|
|
* linux/include/linux/cpu_cooling.h
|
|
*
|
|
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
|
|
* Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org>
|
|
*
|
|
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation; version 2 of the License.
|
|
*
|
|
* This program is distributed in the hope that it will be useful, but
|
|
* WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
|
|
* General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License along
|
|
* with this program; if not, write to the Free Software Foundation, Inc.,
|
|
* 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
|
|
*
|
|
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
*/
|
|
|
|
#ifndef __CPU_COOLING_H__
|
|
#define __CPU_COOLING_H__
|
|
|
|
#include <linux/of.h>
|
|
#include <linux/thermal.h>
|
|
#include <linux/cpumask.h>
|
|
|
|
struct cpufreq_policy;
|
|
|
|
typedef int (*get_static_t)(cpumask_t *cpumask, int interval,
|
|
unsigned long voltage, u32 *power);
|
|
typedef int (*plat_mitig_t)(int cpu, u32 clip_freq);
|
|
|
|
struct cpu_cooling_ops {
|
|
plat_mitig_t ceil_limit, floor_limit;
|
|
};
|
|
|
|
#ifdef CONFIG_CPU_THERMAL
|
|
/**
|
|
* cpufreq_cooling_register - function to create cpufreq cooling device.
|
|
* @policy: cpufreq policy.
|
|
*/
|
|
struct thermal_cooling_device *
|
|
cpufreq_cooling_register(struct cpufreq_policy *policy);
|
|
|
|
struct thermal_cooling_device *
|
|
cpufreq_power_cooling_register(struct cpufreq_policy *policy,
|
|
u32 capacitance, get_static_t plat_static_func);
|
|
|
|
struct thermal_cooling_device *
|
|
cpufreq_platform_cooling_register(const struct cpumask *clip_cpus,
|
|
struct cpu_cooling_ops *ops);
|
|
|
|
void cpu_limits_set_level(unsigned int cpu, unsigned int max_freq);
|
|
|
|
/**
|
|
* of_cpufreq_cooling_register - create cpufreq cooling device based on DT.
|
|
* @np: a valid struct device_node to the cooling device device tree node.
|
|
* @policy: cpufreq policy.
|
|
*/
|
|
#ifdef CONFIG_THERMAL_OF
|
|
struct thermal_cooling_device *
|
|
of_cpufreq_cooling_register(struct device_node *np,
|
|
struct cpufreq_policy *policy);
|
|
|
|
struct thermal_cooling_device *
|
|
of_cpufreq_power_cooling_register(struct device_node *np,
|
|
struct cpufreq_policy *policy,
|
|
u32 capacitance,
|
|
get_static_t plat_static_func);
|
|
#else
|
|
static inline struct thermal_cooling_device *
|
|
of_cpufreq_cooling_register(struct device_node *np,
|
|
struct cpufreq_policy *policy)
|
|
{
|
|
return ERR_PTR(-ENOSYS);
|
|
}
|
|
|
|
static inline struct thermal_cooling_device *
|
|
of_cpufreq_power_cooling_register(struct device_node *np,
|
|
struct cpufreq_policy *policy,
|
|
u32 capacitance,
|
|
get_static_t plat_static_func)
|
|
{
|
|
return NULL;
|
|
}
|
|
#endif
|
|
|
|
/**
|
|
* cpufreq_cooling_unregister - function to remove cpufreq cooling device.
|
|
* @cdev: thermal cooling device pointer.
|
|
*/
|
|
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
|
|
|
|
extern void cpu_cooling_max_level_notifier_register(struct notifier_block *n);
|
|
extern void cpu_cooling_max_level_notifier_unregister(struct notifier_block *n);
|
|
extern const struct cpumask *cpu_cooling_get_max_level_cpumask(void);
|
|
#else /* !CONFIG_CPU_THERMAL */
|
|
static inline struct thermal_cooling_device *
|
|
cpufreq_cooling_register(struct cpufreq_policy *policy)
|
|
{
|
|
return ERR_PTR(-ENOSYS);
|
|
}
|
|
static inline struct thermal_cooling_device *
|
|
cpufreq_power_cooling_register(struct cpufreq_policy *policy,
|
|
u32 capacitance, get_static_t plat_static_func)
|
|
{
|
|
return NULL;
|
|
}
|
|
|
|
static inline struct thermal_cooling_device *
|
|
of_cpufreq_cooling_register(struct device_node *np,
|
|
struct cpufreq_policy *policy)
|
|
{
|
|
return ERR_PTR(-ENOSYS);
|
|
}
|
|
|
|
static inline struct thermal_cooling_device *
|
|
of_cpufreq_power_cooling_register(struct device_node *np,
|
|
struct cpufreq_policy *policy,
|
|
u32 capacitance,
|
|
get_static_t plat_static_func)
|
|
{
|
|
return NULL;
|
|
}
|
|
|
|
static inline struct thermal_cooling_device *
|
|
cpufreq_platform_cooling_register(const struct cpumask *clip_cpus,
|
|
struct cpu_cooling_ops *ops)
|
|
{
|
|
return NULL;
|
|
}
|
|
|
|
static inline
|
|
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
|
|
{
|
|
return;
|
|
}
|
|
|
|
static inline
|
|
void cpu_cooling_max_level_notifier_register(struct notifier_block *n)
|
|
{
|
|
}
|
|
|
|
static inline
|
|
void cpu_cooling_max_level_notifier_unregister(struct notifier_block *n)
|
|
{
|
|
}
|
|
|
|
static inline const struct cpumask *cpu_cooling_get_max_level_cpumask(void)
|
|
{
|
|
return cpu_none_mask;
|
|
}
|
|
#endif /* CONFIG_CPU_THERMAL */
|
|
|
|
#endif /* __CPU_COOLING_H__ */
|