Suman Anna a6a6022871 omap: mailbox: correct OMAP4 reset logic
OMAP4 mailbox has a different register set. There is
no MAILBOX_SYSSTATUS register. The reset is indicated
with the SOFTRESET bit of the MAILBOX_SYSCONFIG register
itself. This bit should read 0 for a successful Reset.
Also, the SOFTRESET bit occupies bit0 and not bit1 as with
previous generations.

Signed-off-by: Suman Anna <s-anna@ti.com>
Acked-by: Hiroshi DOYU <Hiroshi.DOYU@nokia.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
2010-02-23 15:29:21 -08:00
..
2009-12-16 07:20:12 -08:00
2010-02-12 08:51:58 -08:00
2010-02-09 09:46:23 +01:00
2010-01-14 09:05:26 -05:00