mirror of
https://github.com/rd-stuffs/msm-4.14.git
synced 2025-02-20 11:45:48 +08:00
The PDC wakeup value must be equal or earlier than the QTimer value that is set to wake up the system. This is to ensure that the PDC system is awake before the timer. Read the CVAL from the timer and program the PDC wakeup value. Ensure the PDC value is updated after calling tick_broadcast_enter(). Change-Id: I291fd2dd80bed4de19119c548d985ace2ad0c070 Signed-off-by: Lina Iyer <ilina@codeaurora.org>