Christian Pellegrin c01106e573 parport_serial: netmos 9855 fix
Fix wrong netmos 9855 serial port configuration.

On loading only one serial port was present and it wasn't working.  After
looking in the data sheet I realized that the base address was wrong.  For
further reference here is lspci and relevant dmesg output:

02:00.0 Communication controller: NetMos Technology PCI 9855 Multi-I/O
Controller (rev 01) (prog-if 02)
        Subsystem: LSI Logic / Symbios Logic Unknown device 0022
        Flags: medium devsel, IRQ 19
        I/O ports at df00 [size=8]
        I/O ports at de00 [size=8]
        I/O ports at dd00 [size=8]
        I/O ports at dc00 [size=8]
        I/O ports at db00 [size=8]
        I/O ports at da00 [size=16]

parport1: PC-style at 0xdd00 [PCSPP,TRISTATE]
parport2: PC-style at 0xdf00 [PCSPP,TRISTATE,EPP]
0000:02:00.0: ttyS0 at I/O 0xdb00 (irq = 19) is a 16550A
0000:02:00.0: ttyS1 at I/O 0xda00 (irq = 19) is a 16550A

Signed-off-by: Christian Pellegrin <chripell@fsfe.org>
Cc: Thomas Richter <thor@math.TU-Berlin.DE>
Cc: Bjorn Helgaas <bjorn.helgaas@hp.com>
Cc: Martin Schitter <ms@gewi.kfunigraz.ac.at>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2008-02-06 10:41:08 -08:00
..
2008-02-05 09:44:22 -08:00
2008-02-06 10:41:01 -08:00
2008-02-05 09:44:23 -08:00
2008-02-03 17:12:34 +02:00
2008-02-05 09:44:13 -08:00
2008-02-06 10:41:01 -08:00
2008-02-04 23:50:03 +11:00
2008-02-06 10:41:02 -08:00
2008-02-03 17:21:01 +02:00
2008-02-06 10:41:03 -08:00
2008-02-03 17:22:34 +02:00
2008-02-06 10:41:08 -08:00
2008-02-06 10:41:01 -08:00
2008-01-31 11:25:51 +11:00
2008-02-06 10:41:01 -08:00
2008-02-03 17:30:25 +02:00
2008-02-06 10:41:07 -08:00
2008-02-06 10:41:01 -08:00
2008-02-04 23:50:13 +11:00
2008-02-05 09:44:12 -08:00
2008-02-05 09:44:12 -08:00